Main code 53
53-6
Purpose
Adjustment
Function (Content)
Used to adjust the DSPF width detection level.
Section
SPF/DSPF
Item
Operation
Operation/Procedure Adjust the machine SPF document tray size
adjustment.
1) Extend the guide to MAX. position, select 1,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
2) Move the guide to A4R position, select 2,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
3) Move the guide to A5R position, select 3,
and press START.
When COMPLETE is displayed,
press CUSTOM SETTING to return to the
initial screen.
4) Move the guide to MIN. position, select 4,
and press START.
When COMPLETE is displayed,
the adjustment is completed.
If ERROR is displayed in procedures 1) - 4),
repeat the adjustment again.
*
This adjustment is performed only when the width detection volume
is replaced.
Normally use SIM 53-7 for input.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1. MAX. POSITION
2. POSITION 1
3. POSITION 2
4. MIN. POSITION
Select 1, and
press [START] key.
Press [CUSTOME SETTING] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX. POSITION ... COMPLETE (or "ERROR")
Select 2, and
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or "ERROR")
Select 3, and
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or "ERROR")
Select 4, and
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN. POSITION ... COMPLETE (or "ERROR")
1
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
Press [CUSTOME SETTING] key.
AR-M350 SIMULATIONS 10-55
53-7
Purpose
Adjustment, setup, operation data output, check
(display, print)
Function (Content)
Used to enter the adjustment value of SPF width
detection.
Section
DSPF
Item
Operation
Operation/Procedure Enter the adjustment value (indicated on the
back of SPF) of SPF document tray size.
SIMULATION 53-7
SPF TRAY ADJUSTMENT (MANUAL). SELECT 1-4, AND PRESS START.
1. MAX. POSITION:
66
2. POSITION 1:
456
3. POSITION 2:
713
4. MIN. POSITION:
791
Press [START] key.
SIMULATION 53-7
SPF TRAY ADJUSTMENT (MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1. MAX. POSITION
<List of set values>
1
Max. width
2
Adjustment point 1
3
Adjustment point 2
4
Min. width
1
Press [CUSTOM SETTING] key.
66
Initial value
Range
66
0 - 1023
456
713
791