Sharp AR-M350U Service Manual page 172

Options ar-p14
Hide thumbs Also See for AR-M350U:
Table of Contents

Advertisement

Main code 25
25-1
Purpose
Operation test, check
Function (Content)
Used to check the operations of the main drive
section (excluding the scanner (reading) section)
and the toner density sensor. (The toner density
sensor output can be monitored.)
Section
Drive
Item
Operation
Operation/Procedure the toner density control sensor value is
displayed. Press START key, and the main motor
will rotate to start monitoring the toner density
control sensor.
SIMULATION 25-1
DV MONITOR. PRESS START.
Press [START] key.
SIMULATION 25-1
DV MONITOR. EXECUTING...
25-2
Purpose
Setup
Function (Content)
Used to initialize the toner density when
replacing developer. (Auto adjustment)
Section
Process
(OPC drum, developing, transfer, cleaning)
Item
Operation/Procedure The toner density control sensor value is
displayed. Press START key, and the main motor
will rotate. After stirring for 2 min, the toner
density control sensor value is sampled 10 times
and the average value is stored.
Note: Open front cover before entering SIM for Auto adjust.
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. PRESS START.
Press [START] key.
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. EXECUTING...
128
Press [CUSTOM SETTING] key to stop.
Or stop after 2min.
128
128
Press [CUSTOM SETTING] key to stop.
Or stop after 2min.
128
AR-M350 SIMULATIONS 10-28
Main code 26
26-3
Purpose
Setup
Function (Content)
Used to set the specification mode of the auditor.
Setup must be made according to the use
conditions under auditor.
Section
Auditor
Item
Spec
Operation/Procedure The auditor setting is performed. (Default: 1)
SIMULATION 26-3
AUDITOR SETUP. SELECT 1-3, AND PRESS START.
1. P10
2. VENDOR
3. OTHERS
26-5
Purpose
Setup
Function (Content)
Used to set the count mode of the total counter
and the maintenance counter.
Section
Item
Spec
Operation/Procedure 1) Setting of the count-up number of A3/WLT
paper passing (1 or 2) is made.
The current set value is highlighted on the
right side of the item.
2) Setting of the count-up number of the selected
counter is made.
1: 1 count up
2: 2 counts up (Default : 2)
SIMULATION 26-5
A3(LEDGER) COUNT UP MODE SETTING. SELECT 1-3, AND PRESS
START.
1
1. TOTAL COUNTER
2. MAINTENANCE(DRUM) COUNTER
1
3. DV CARTRIDGE COUNTER
Press [START] key.
SIMULATION 26-5
A3(LEDGER) COUNT UP MODE SETTING. SELECT 1-2, AND PRESS
START.
1. TOTAL COUNTER
(1 : 1COUNT UP‚ 2 : 2COUNT UP)
<List of target counters>
1
Total counter
2
Maintenance counter/drum cartridge counter
3
Developer cartridge counter
1
1
1
Press [CUSTOM SETTING] key.
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m450uAr-m350nAr-m450n

Table of Contents