accessory will stop transmitting until the time limit is reached.
For example, when a device has a duty cycle limit of 1%, it is only allowed
to transmit 36 seconds in 1 hour. After this, it will stop transmitting until the
1 hour limit is reached.
DHC accessories fully comply to this limitation and use 2 frequency bands
with a duty cycle of respectively 1 % and 10%.
During normal operation of the DHC accessories, this limit is not usually
reached. However it is possible that the limit is reached during start-up or
during a fresh installation of a system. In this case, the LED of the accessory
lights up red. It may be non-responsive for a short period (max. 1 hour),
until the time restriction for transmission has expired. After this period, it will
operate normal again.
8.2

Error codes and flashing sequences

8.2.1

Flashing sequences of the system LED

Flashing code
Short orange
flashing
1x long green
lighting
1x long red
lighting
Short orange
flashing (every 10
seconds)
20
Meaning
Radio transmission/
attempting to transmit/
data transmission
Transmission
confirmed
Transmission/operation
failed or duty cycle limit
is reached
Connection mode
active
Solution
Wait until the transmission is
completed.
Continue operation.
Try again (see „8.1 Duty
cycle" on page 19).
Enter the last four numbers
of the device serial number
for confirmation (see „6.4
Connecting further DHC
accessories" on page 18).