Siemens SIMATIC RF170C Operating Instructions Manual page 31

Table of Contents

Advertisement

Table 5- 1
Parameters in the "Module parameters" parameter group
Parameter
User Mode
MOBY Mode
Transmission
speed
Diagnostics
messages
SIMATIC RF170C
Operating Instructions, 02/2022, J31069-D0176-U001-A6-7618
Parameter value
Ident profile/RFID
standard profile
FB 45 / FC 45
FB 55 / FC 55
RF200/RF300/RF600;
MV4x0; MOBY U/D
MOBY I/E
MV3xx
Freeport protocol
RF300 filehandler
19.2 kBd
57.6 kBd
115.2 kBd
None
Hard errors
5.2 Configuration via STEP 7 (Basic/Professional)
Default value
Description
Ident profile/RFID
Selection depends on the communications
standard profile
module and Ident system being used. With this
parameter you select the block:
RF200/RF300/RF600
Selection depends on the communications
; MV4x0; MOBY U/D
module and Ident system being used. With this
parameter, you set the mode of the
communications module.
Normal addressing: The transponder is
addressed with physical addresses.
115.2 kBd
Selection depends on the communications
module and Ident system being used. With this
parameter you set the transmission speed
between the communications module and
reader.
When the RFID reader is connected: After
changing the transmission speed, the reader
must be turned off and on again (cycle power).
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected in the firmware
of the reader.
None
Selection depends on the communications
module and Ident system being used. With this
parameter you set whether hardware
diagnostics messages will be reported.
Parameter settings
Ident profile/RFID standard profile:
The program block for the Ident profile/RFID
standard profile is used on the controller.
FB 45 / FC 45:
Single tag mode FB 45 (PROFIBUS/PROFINET)
or FC 45 (PROFIBUS) is used on the
controller.
FB 55 / FC 55:
Multitag mode. FB 55 (PROFIBUS/PROFINET)
or FC 55 (PROFIBUS) is used on the
controller.
RF200/RF300/RF600; MV4x0; MOBY U/D
MOBY I/E
MV3xx
Freeport protocol
RF300 filehandler
1)
None:
Apart from standard diagnostics, no other
alarms are generated.
Hard errors:
Critical hardware errors are reported by the
S7 diagnostics.
31