Steam Dispensing With Autosteam Selector (When Provided) - Cimbali Ambassador SE E91 Manual

Table of Contents

Advertisement

12.3 Steam dispensing with Autosteam selector (when provided)

Machines equipped with the AUTOSTEAM (STOP STEAM)
dispensing system have the "
set temperature is reached" function, and can rapidly heat
and froth milk.
Select the type of milk you desire with the position of the milk
frother lever (11).
In particular:
- lever down: foamed milk;
- lever up: heated milk.
Insert the steam nozzle (9) into a suitable container, making
sure the bulb is completely immersed in the milk.
Press the key (16) to start the dispensing.
N.B.: When the set temperature is reached, steam supply
stops automatically.
Steam can be stopped at any time (even if the set temperature
Temperature setting
The temperature setting for the "Stop Steam" function is factory
set at 72°C (161°F) and is therefore not set by the user.
Nevertheless, the standard setting can be changed within the
range of 45 and 85°C (113÷185°F).
To make this change:
- switch off the machine;
- remove the left side
- adjust the setting (R) on the Autosteam card, keeping in
mind the corresponding number of notches and
temperature:
notch 0 = ~45°C (113°F)
notch 10 = ~85°C (185°F)
increment between the 2 notches = ~4°C (39.2°F)
The indication of intermediate temperatures is approximate;
after each adjustment, please use a thermometer to determine
the actual set temperature.
The ideal setting for milk frothing is set in the factory. If additional
(A):
- counterclockwise: more air > more frothy milk
- clockwise: less air > less frothy milk
Note: even slight turns of the valve (A) can make a great
difference in how the milk is frothed.
Correct alignment of the steam thermocouple is
performed in the factory: for this reason, do not
turn the adjusting screw (T).
16
9
16
View of the right side of the machine
33
11
16
9
Frothed milk
A
11
Hot milk
T
R