S1 series standard inverter
Set
value
10
Frequency increase (UP)
Frequency decrease
11
Clear frequency
12
increase/decrease setting
Switching between A setting
13
and B setting
Switching between
14
combination setting and A
Switching between
15
combination setting and B
16
Multi-step speed terminal 1
17
Multi-step speed terminal 2
18
Multi-step speed terminal 3
19
Multi-step speed terminal 4
20
Multi-step speed pause
Acceleration/deceleration
21
time selection 1
Function
(DOWN)
setting
setting
Used to change the frequency-increase/decrease
command when the frequency is given by external
terminals.
K1
K2
K3
The terminal used to clear frequency-increase/decrease
setting can clear the frequency value of auxiliary channel
set by UP/DOWN, thus restoring the reference frequency
to the frequency given by main reference frequency
command channel.
This function is used to switch between the frequency
setting channels.
A frequency reference channel and B frequency
reference channel can be switched by no. 13 function;
the combination channel set by P00.09 and the A
frequency reference channel can be switched by no. 14
function; the combination channel set by P00.09 and the
B frequency reference channel can be switched by no. 15
function.
16-step speeds can be set by combining digital states of
these four terminals.
Note: Multi-step speed 1 is low bit, multi-step speed 4
is high bit.
Multi-step
Multi-step
speed 4
speed 3
BIT3
BIT2
Pause multi-step speed selection function to keep the set
value in present state.
Use these two terminals to select four groups of
acceleration/decoration time.
-73-
Description
UP terminal
DOWN terminal
UP/DOWM
Zeroing terminal
COM
Multi-step
speed 2
BIT1
Multi-step
speed 1
BIT0