S1 series standard inverter
Function
code
Corresponding setting of
P05.30
P05.31
Intermediate value 1 of AI2
Corresponding setting of
P05.32
intermediate value 1 of AI2
P05.33
Intermediate value 2 of AI2
Corresponding setting of
P05.34
intermediate value 2 of AI2
P05.35
Upper limit value of AI2
Corresponding setting of
P05.36
P05.37
Input filter time of AI2
P05.38
Corresponding setting of the
P05.39
P05.40
Middle value of AI3
Corresponding middle
P05.41
P05.42
Corresponding setting of
P05.43
the upper limit of AI3
P05.44
AI3 input filter time
Lower limit frequency of
P05.45
Corresponding setting of
P05.46
lower limit frequency of
Upper limit frequency of
P05.47
Corresponding setting of
P05.48
upper limit frequency of
HDI/HDIA frequency input
P05.49
Lower limit frequency of
P05.50
Corresponding setting of
P05.51
lower limit frequency of HDIB
Name
lower limit of AI2
upper limit of AI2
Lower limit of
AI3
lower limit of AI3
setting of AI3
Upper limit of AI3
HDI/HDIA
HDI/HDIA
HDI/HDIA
HDI/HDIA
filter time
HDIB
Detailed parameter description
-100.0%–100.0%
P05.29–P05.33
-100.0%–100.0%
P05.31–P05.35
-100.0%–100.0%
P05.33–10.00V
-100.0%–100.0%
0.000s–10.000s
-10.00V–P05.39
-100.0%–100.0%
P05.38–P05.42
-100.0%–100.0%
P05.40–10.00V
-100.0%–100.0%
0.000s–10.000s
0.000 KHz – P05.41
-100.0%–100.0%
P05.39 –50.000KHz
-100.0%–100.0%
0.000s–10.000s
0.000 KHz – P05.47
-100.0%–100.0%
-68-
Default
value
-100.0%
0.00V
0.0%
0.00V
0.0%
10.00V
100.0%
0.100s
-10.00V
-100.0%
0.00V
0.0%
10.00V
100.0%
0.100s
0.000KHz
0.0%
50.000KHz
100.0%
0.030s
0.000KHz
0.0%