S1 series standard inverter
Function
Communication-based
value setting
Address
0006H: Coast to stop (emergency stop)
0007H: Fault reset
0008H: Jogging to stop
Communication-based frequency setting (0–
2001H
Fmax, unit: 0.01 Hz)
PID setting, range (0–1000, 1000 corresponding
2002H
to 100.0%)
PID
feedback,
2003H
corresponding to 100.0%)
Torque
2004H
corresponding to 100.0% of the rated current of
the motor)
Setting of the upper limit of the forward running
2005H
frequency (0–Fmax, unit: 0.01 Hz)
Setting of the upper limit of the reverse running
2006H
frequency (0–Fmax, unit: 0.01 Hz)
Upper limit of the electromotion torque (0–3000,
2007H
1000 corresponding to 100.0% of the rated
current of the inverter)
Upper limit of the brake torque (0–3000, 1000
2008H
corresponding to 100.0% of the rated current of
the motor)
Special control command word:
Bit1–0 =00: Motor 1
Bit2: =1 Torque control disabled =0: Torque
control cannot be disabled
2009H
Bit3: =1 Power consumption reset to 0
=0: Power consumption not reset
Bit4: =1 Pre-excitation
disabled
Bit5: =1 DC brake =0: DC brake disabled
Virtual input terminal command, range: 0x000–
200AH
0x1FF
Virtual output terminal command, range: 0x00–
200BH
0x0F
Voltage setting (used when V/F separation is
200CH
implemented)
(0–1000, 1000 corresponding to 100.0% of the
Data description
range
setting
(-3000–+3000,
=01: Motor 2
=10: Motor 3
=11: Motor 4
-189-
(0–1000,
1000
1000
=0: Pre-excitation
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W