Installing the Ductwork

Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only insulated ductwork
to minimize cooling loses, prevent sweating, and to reduce noise.
Use ductwork on the condenser section to redirect or absorb sound, to bring in outside air to the unit inlet,
and/or to exhaust the hot air out of the ambient space
安装管道系统
用通风管道连接酒窖, 应该尽量使用带隔热绝缘的通风管道,以减少冷气流失,防止产生冷
凝水, 也减少噪音。
冷凝部分(段)使用风管可起定向消声作用,也可以把室外空气送到主机进风口,和 / 或 将
热气排出室内环境空间。
NOTE: Do not exce
Recommended Insulated Flexible Ductwork Sizing Chart
Model
WG40
WG75
WG100
WG175
Avoid crimping the flexible ducts. This chokes down the inside area and reduces the airflow
Be sure all ducts and surface in contact with the airflow are insulated
Uninsulated ducts and surfaces cause bare exposed metal surfaces to sweat,
further degradation of the insulation and a loss of equipment cooling capacity.
65
ed
a total of 7.5 metres for each length of ductwork run.
每条管道长度不要超过 7.5 米。
Evaporator Coil
Single
Double
Outlet
Outlet
Inlet
200
200
250
250
250
250
300
300
RISK OF DAMAGE TO EQUIPMENT
causing the unit to operate erratically.
and have a vapor barrier on the outside surface.
注:
Condenser Coil
Single
Outlet
Inlet
150
200
200
250
200
250
250
300
CAUTION
注意
Double
Outlet
200
150
250
200
250
200
300
250