Finishing Work And Cleaning; Storing For Long Periods Of Time - WAGNER Unica 4-270 Translation Of The Original Operating Manual

Medium pressure double diaphragm pump
Hide thumbs Also See for Unica 4-270:
Table of Contents

Advertisement

EDITION 09 /2015
OPERATING MANUAL
5.3

FINISHING WORK AND CLEANING

Note
The device should be cleaned for maintenance purposes, etc. Ensure that no remaining
material dries and sticks.
Procedure:
1. Follow the procedure foreseen to stop the pump -> chapter 5.2.5
2. Follow the procedure foreseen for washing -> chapter 5.2.3.
3. Clean and check the suction system and, in particular, the suction fi lter.
4. When using a high-pressure fi lter: Clean and check the fi lter insert
5. Clean the external part of the system.
6. Fill the system with detergent following the instructions given in paragraph 5.2.4
"Filling with working fl uid".
Gas mixtures can explode if there is an incompletely filled
pump!
Danger to life from flying parts.
SIHI_41_0025_GB
5.4

STORING FOR LONG PERIODS OF TIME

When storing the pump for long periods of time it is necessary to thoroughly clean it and
protect it from corrosion. Replace the water or the solvent in the pump delivery circuit
with a suitable preservative oil.
Procedure:
1. Carry out Paragraph 5.3 „Shutting down and cleaning", points 1 through 6.
2. Fill the system with conservative liquid following the instructions given in paragraph
5.2.4.
3. Protect the air motor with pneumatic oil: connect an oiler to the compressed air inlet
and have the pump perform a few double strokes.
PART NO. ZZB028ENG
WARNING
Ensure that the pump and suction system are always
completely filled with cleaning agent or working medium.
Do not spray the unit empty after cleaning.
Unica 4-270 N
.
29

Advertisement