Updating The Mcu Firmware - Ublox C102-F9R User Manual

Application board
Table of Contents

Advertisement

A configuration entry can be overwritten by sending a new CONFIG SET message with the same unit
and source.
All configuration entries can be deleted with the CONFIG CLEAR message.

4.5 Updating the MCU firmware

New MCU firmware and corresponding tool versions may be released e.g. to support new features or
to increase the performance of the application. To update the firmware, the following equipment is
required:
-
Silicon Labs IDE or Flash Programming Utilities software [5], and
-
USB debug adapter for 8-bit MCUs [6]
Follow these steps to flash the new firmware:
1. Power up the device.
2. Connect the debugger to the 10-pin rear connector.
3. If using the Silicon Labs IDE:
a. Select Debug > Connect to connect the Debugger to the MCU.
b. Select Debug > Download
c. Select Download to start the flashing process.
4. If using Flash Programming Utilities, follow the instructions accompanying the software.
5. After the device is flashed, disconnect the debugger and reboot the device.
6. Confirm that the firmware version string matches by either checking what the MCU outputs
during bootup, or by sending a FW GET command.
UBX-20029244 - R03
C1-Public
object file
and input the correct file to the opened window.
Configurable CAN interface
C102-F9R - User guide
Page 13 of 32

Advertisement

Table of Contents
loading

Table of Contents