4.2

Start-up behavior

Following connection to the grid, the auxiliary power supply starts, and the devices are supplied. During the
output capacitor pre-charging phase, as seen in Figure 6, both channels are bypassed by the D20- an ultrafast
high-voltage rectifier, and the inrush current is limited by two NTC resistors. Once output voltage reaches about
230 V
, K1 relay turns on and two NTC are shorted, enabling the converter works with high efficiency.
DC
The board is designed to start in both no load condition and full load condition. Figure 18 and Figure 19 show
the converter full-load start-up waveforms at V
Figure 18
Full load start-up at V
User guide
Power factor
1500
2000
2500
Output power (watt)
180VAC
230VAC
=180 V
and V
IN
AC
Vout=Blue, V
=Yellow, I
GE
=180 V
IN
AC