5 kW two-channel interleaved CCM PFC EVAL board
IKW40N65WR5, IDW60C65D1 and 1ED44175 in high frequency PFC application

Safety precautions

Safety precautions
Note:
Please note the following warnings regarding the hazards associated with development systems.
Table 1
Safety precautions
User guide
Warning: The DC link potential of this board is up to 400 VDC. When measuring voltage
waveforms by oscilloscope, high voltage differential probes must be used. Failure to do
so may result in personal injury or death.
Warning: The evaluation board contains DC bus capacitors which take time to
discharge after removal of the main supply. Before working on the drive system, wait
five minutes for capacitors to discharge to safe voltage levels. Failure to do so may
result in personal injury or death.
Warning: The evaluation board is connected to the grid input during testing. Hence,
high-voltage differential probes must be used when measuring voltage waveforms by
oscilloscope. Failure to do so may result in personal injury or death.
Caution: The heat sink and device surfaces of the evaluation or reference board may
become hot during testing. Hence, necessary precautions are required while handling
the board. Failure to comply may cause injury.
Caution: Only personnel familiar with the drive, power electronics and associated
machinery should plan, install, commission and subsequently service the system.
Failure to comply may result in personal injury and/or equipment damage.
Caution: The evaluation board contains parts and assemblies sensitive to
electrostatic discharge (ESD). Electrostatic control precautions are required when
installing, testing, servicing or repairing the assembly. Component damage may result
if ESD control procedures are not followed. If you are not familiar with electrostatic
control procedures, refer to the applicable ESD protection handbooks and guidelines.
Caution: A drive that is incorrectly applied or installed can lead to component damage
or reduction in product lifetime. Wiring or application errors such as undersizing the
motor, supplying an incorrect or inadequate AC supply, or excessive ambient
temperatures may result in system malfunction.
Caution: The evaluation or reference board is shipped with packing materials that
need to be removed prior to installation. Failure to remove all packing materials that
are unnecessary for system installation may result in overheating or abnormal
operating conditions.