5.3.4 SENS (Failure monitoring)

Command
SENS
This command is used to activate/deactivate the monitoring functions (output current and internal failures) of
the module.
ON:
All monitoring functions are active. Detected failures can be reset by deactivating the ENABLE input.
This mode should be used in case of active enabling and monitoring by a PLC (READY signal).
OFF:
No monitoring function is active.
AUTO:
Auto reset mode. All monitoring functions are active. If the failure does not exist anymore, the mod-
ule automatically resumes to work.
Normally the monitoring functions are always active because otherwise no errors are detectable via
the READY output. Deactivating is possible especially for troubleshooting.
AUTO MODE: The module checks each second the actual failure status, which will (in case of a per-
sistent error) trigger the LED and the READY output for a short time.

5.3.5 FUNCTION (Choosing operation mode)

Command
FUNCTION
This parameter allows you to adapt the amplifier to valves with one solenoid (e.g. pressure valves) or to such
with two solenoids (directional valves).

5.3.6 CCMODE (Activation of the characteristic linearization)

Command
CCMODE
This command will be used for activation or deactivation of the characteristics linearization (CC, CCA and
CCB). Through deactivating this parameter a simple and quick estimation of the linearization is possible.
CAUTION: If CC command is used, parameters MIN, MAX and TRIGGER have to be considered.
CC and those commands affect each other. Pay attention to that if it is necessary to use both kind
of settings at the same time.