Technical Data - WEST PAM-199-P-PDP Technical Documentation Manual

Universal power amplifier with profibusdp interface
Table of Contents

Advertisement

4.5

Technical data

Power supply (U
Power consumption max.
External fuse
Digital inputs
OFF
ON
Input resistance
Digital outputs
OFF
ON
Maximum current
PWM output
Max. output current
Frequency
Sample time
Solenoid current control
Signal processing
Profibus DP interface
data rate
ID-number
Serial interface
Transmission rate
Housing
Material
Flammability class
Weight
Protection class
Temperature range
Storage temperature
Humidity
Connections
Communication
Profibus
Plug connectors
PE
EMC
Page 16 of 37
)
b
12... 30 (incl. ripple)
[VDC]
[W]
max. 2.5 + Power of the connected coils
[A]
3 medium time lag
[V]
< 2
[V]
> 10
[kOhm]
25
[V]
< 2
[V]
max. Ub
[mA]
50
Wire break and short circuit monitored
[A]
2.6
61... 2604 selectable in defined steps
[Hz]
[µs]
125
[ms]
10
[kbit/s]
9.6,19.2, 93.75, 187.5, 500, 1500, 3000, 6000,
12000
-
1810h
-
USB - virtual COM Port
9.6... 115.2
[kBaud]
Snap -on module acc. EN 50022
-
PA 6.6 polyamide
-
V0 (UL94)
[kg]
0.310
[IP]
20
-20... 60
[°C]
-20... 70
[°C]
[%]
< 95 (non-condensing)
-
USB type B
D-SUB p pin
4-pole terminal blocks
via the DIN mounting rail
EN
61000-6-2: 8/2005
EN
61000-6-4: 6/2007 ; A1:2011
PAM-199-P-PDP
05.06.2020

Advertisement