Parameter List 196 - WEST PAM-199-P-PDP Technical Documentation Manual

Universal power amplifier with profibusdp interface
Table of Contents

Advertisement

5.2

Parameter list 196

Group
Command
Basic parameters
LG
MODE
PDPADR
SENS
FUNCTION
CCMODE
Input signal adaptation
AA:UP
AA:DWN
AB:UP
AB:DOWN
Output signal adaptation
CCA
CCB
MIN:A
MIN:B
MAX:A
MAX:B
TRIGGER
Parameters of the power stage
CURRENT
DAMPL:A
DAMPL:B
DFREQ:A
DFREQ:B
PWM:A
PWM:B
ACC
PPWM:A
PPWM:B
IPWM:A
IPWM:B
Page 18 of 37
Default
Unit
EN
-
STD
-
126
-
AUTO
-
196
-
OFF
-
100
ms
100
ms
100
ms
100
ms
X
Y
-
X
Y
-
0
0.01 %
0
0.01 %
10000
0.01 %
10000
0.01 %
200
0.01 %
1000
mA
500
0.01 %
500
0.01 %
121
Hz
121
Hz
2604
Hz
2604
Hz
ON
-
7
-
7
-
40
-
40
-
PAM-199-P-PDP
Description
Changing language help texts
Parameter view
Profibus device address
Malfunction monitor
Operation mode
Activation and deactivation of the characteristic linearization
Command signal ramp times channel A
Command signal ramp times channel B
Free definable characteristic linearization
Deadband compensation
Output scaling
Deadband compensation trigger point
Rated solenoid current
Dither amplitude
Dither frequency
PWM frequency
Current loop auto adjustment
P-Gain of the current loop
I-Gain of the current loop