7.4 Commands via Profibus

16 Bytes are send to the module.
Byte
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Coding of the control word:
Bit
7
6
5
4
3
2
1
0
3
Hardware and software ENABLE are linked with each other. Means the system is only ready if both signals are available.
Page 32 of 37
Function
Control word High
Control word
Low
Demand value
channel A
Demand value
channel A
Demand value channel B High
Demand value channel Low
Parameter adress High
Parameter adress Low
-
-
Parameter value MSB
Parameter value ...
Parameter value ...
Parameter value LSB
-
-
Byte 1 – Control word Hi
Function
3
Enable
channel A
Enable channel B
PARAMODE
PARAVALID
PAM-199-P-PDP
Not used here
...0xc001 / ...0x3fff for +/- 100 %
High
0x0000... 0x3fff for 0... 100 %
Low
0x0000... 0x3fff for 0... 100 %
0x2001 to 0x2035
Not used here
0x0000...0x1D4C0 depending on the
prarameter
Remark
1 = Enable
1 = Enable
1 = active
Rising edge