5.2.4 CCMODE (Activation of the characteristic linearization)

Command
CCMODE
This command will be used for activation or deactivation of the characteristics linearization. Through deactivat-
ing this parameter a simple and quick estimation of the linearization is possible.
CAUTION: If CC command is used, parameters MIN, MAX and TRIGGER have to be considered.
CC and those commands affect each other. Pay attention to that if it is necessary to use both kind
of settings at the same time. Otherwise try to use only one of this options for those settings.

5.2.5 SENS (Failure monitoring)

Command
SENS
This command is used to activate/deactivate the monitoring functions (4... 20 mA sensors, output current, sig-
nal range and internal failures) of the module.
ON:
All monitoring functions are active. Detected failures can be reset by deactivating the ENABLE input.
This mode should be used in case of active enabling and monitoring by a PLC (READY signal).
OFF:
No monitoring function is active.
AUTO:
Auto reset mode. All monitoring functions are active. If the failure does not exist anymore, the mod-
ule automatically resumes to work.
Normally the monitoring functions are always active because otherwise no errors are detectable via
the READY output. Deactivating is possible especially for troubleshooting.
Page 20 of 33
Parameters
X
x= ON|OFF
Parameters
X
x= ON|OFF|AUTO
PAM-198-P
Unit
-
Unit
-
Group
SYSTEM
Group
SYSTEM
05.06.2020