3.3 Manual parameterization

3.3.1

Parameter overview

The manual adjustment is comparable with the adjustment via potentiometer. Not all parameter of the power
plug are available in this mode
Switch
Parameter
position
0
DEFAULT
1
CURRENT
2
MIN
3
MAX
4
R:UP
5
R:DOWN
6
PWM
7
-
8
-
9
-
3.3.2

Procedural method

1. Press a button or turn the selector switch which activates the manual adjustment mode. The parame-
ter-LED flashes.
2. Select the desired parameter (1... 6) by the selector switch.
3. The parameter LED indicates - by flashing - the parameter mode.
a. At the lower boundary the LED lights only briefly
b. At the upper boundary the LED lights almost continuously
4. Press the UP or DOWN button.
a. A short activation of one of the buttons will change the parameter by a value of app. 1%.
b. A continual activation of one of the buttons will change the parameter continually (up to the
point where the upper or lower boundary is reached).
5. The parameters are stored automatically (app. 1 second after the last parameter adjustment). The
manual adjustment will be finished after 60 seconds.
2
The full functionality of the power plug is available via the PC interface only.
Page 10 of 24
2
.
Setting range
Remark
-
Released only by pressing the button "Up" and "DOWN"
simultaneously. Response: a short and fast flashing of
the LED.
0 = low current range; press button "DOWN"
0 | 1
1 = high current range; press button "UP"
0...60%
Deadband compensation
in relation to the current range
30...100%
Reduction in the maximum current
in relation to the current range
50ms...5sec
Ramp time up
50ms...5sec
Ramp time down
60...1500 Hz
PWM output frequency
No function
No function
No function
PAM-190-P-*-1010
18.08.2015