5 Parameter

5.1

Parameter list

Group
Command
Basic parameters - SYSTEM
MODE
LG
CTRLMODE
CCMODE
SENS
In- and output adaption - IO_CONF
Sensor signal
AIN:X
Command signal
AIN:W
Control signal
SIGNAL:U
One solenoid
VA:OFFSET
Two solenoids
VA:MIN:A
VA:MIN:B
VA:MAX:A
VA:MAX:B
VA:TRIGGER
Command signal adaption - ADAPT
Ramp function
RA:1
RA:2
RA:3
RA:4
Linearization function
CC
Deadband compensation / direction depending scaling
MIN:A
MIN:B
MAX:A
MAX:B
TRIGGER
Page 17 of 33
Default
Unit
---
-
Switching visible parameter group
EN
-
Language selection
CL
-
Open and closed loop selection
OFF
-
Aktivation / Deactivation CC command
AUTO
-
Failure monitoring
U0-10
V
Mathematic scaling function sensor
U0-10
-
Mathematic scaling function demand
2S+
-
Type and polarity of the output signal
0
0,01 %
Zero point setting
0
0,01 %
Minimum control for spring pre-load
0
0,01 %
10000
0,01 %
Maximum control
10000
0,01 %
200
0,01 %
Treshold for minimum control
100
ms
100
ms
Ramp times for command signal
100
ms
100
ms
X
Y-
0,01 %
Parameterizing linearization by 10 points
0
0,01 %
Deadband compensation
0
0,01 %
10000
0,01 %
Output scaling
10000
0,01 %
200
0,01 %
Treshold for deadband compensation
PAM-198-P