SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
MCS--4200/7200 Multi--Channel SATCOM System
(b) The Last Leg Class 3 Faults lists two Class 3 faults per page if Class 3 faults are
present during the last leg. These two sets of lines display Class 3, Level 1
diagnosed, last leg failures. Failures are displayed in chronological order (i.e.,
the most recent detected failure last) with no more than two failures displayed
per page.
(c) The number of LAST LEG CLASS 3 FAULTS pages depends on the number of
failures to report (up to a maximum of 99 pages). When there is an odd number
of failures to report, the odd failure is displayed on a separate page in lines 5, 6,
and 7, and lines 9, 10, and 11 are blank. If there are no failures to report, lines 6,
7, 9, 10, and 11 are blank. Line 5 displays NO FAULT DETECTED beginning in
column 4 if there are no failures to report.
(d) Line 5 and, if applicable, line 9 display the UTC beginning in column 1 and the
ATA number beginning in column 6.
(e) The UTC number is displayed as hh:mm, where hh represents the UTC hours
from 00 to 23, and mm represents the UTC minutes from 00 to 59. The UTC is
the time of the failure reporting as stored in the SDU system failure memory log.
Dashes are displayed if no valid UTC data is available.
(f) The ATA number is displayed as aaaaaa, where aaaaaa represents the ATA
reference number of the reported failure as specified in paragraph 3.E. for each
type of CFDS. For CFDS type none, no ATA number is displayed.
(13) GROUND REPORT Page
(a) Access to this page is from the SAT--N (i.e., SATCOM MAINTENANCE) page.
The purpose of this page is to display Class 1, 2, or 3, Level 1 diagnosed ground
failures that occurred during the last leg. See Figure 6-15 for example pages.
(b) The Ground Report lists two failures per page if failures are detected during the
last leg. These two sets of lines display Class 1, 2, and 3, Level 1 diagnosed,
last leg failures. Failures are displayed in chronological order (i.e., the most
recent detected failure last) with no more than two failures displayed per page.
(c) The number of GROUND REPORT pages depends on the number of failures to
report (up to 99 pages). When there is an odd number of failures to report, the
odd failure is displayed on a separate page in lines 5, 6, and 7, and lines 9, 10,
and 11 are blank. If there are no failures to report, lines 6, 7, 9, 10, and 11 are
blank. Line 5 displays NO FAULT DETECTED beginning in column 4 if there are
no failures to report.
 Honeywell International Inc. Do not copy without express permission of Honeywell.
23- -20- -35
Page 6--85
15 Jul 2006