SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
MCS--4200/7200 Multi--Channel SATCOM System
(b) The Last Leg Report lists two failures per page if a failure is present during the
last leg. These two sets of lines display Class 1 and 2, Level 1 diagnosed, last
leg failures. Failures are displayed in chronological order (i.e., the most recent
detected failure last) with no more than two failures displayed per page. The
number of LAST LEG REPORT pages depends on the number of failures to
report (up to a maximum of 99 pages). When there is an odd number of failures
to report, the odd failure is displayed on a page of its own in lines 5, 6, and 7,
and lines 9, 10, and 11 are blank. If there are no failures to report, lines 6, 7, 9,
10, and 11 are blank. Line 5 displays NO FAULT DETECTED beginning in
column 4 if there are no failures to report.
Page 6--72
23- -20- -35
15 Jul 2006
 Honeywell International Inc. Do not copy without express permission of Honeywell.