7500-M Neutralizer Installation & Startup Guide
This should be left at its default, [F-00]. This will have the system only backwash and rinse once
per service.
4) To change the Service Days:
Service days indicates how often the system will operate and backwash/rinse. The
recommended setting for a neutralizer filter is 7 days.
To set this, change the programming mode to Service Days ( [1‐03D] ). Press the Menu/Confirm
button and use the Up/Down buttons to set it to your desired amount. Press Menu/Confirm to
confirm your input.
5) To change the Backwash Time:
The backwash time is the amount of time (in minutes) that the system will backwash for.
For a neutralizer filter, set the backwash time to 10 minutes [2-10:00]. To change this, set the
programming mode to Backwash Time ( [2‐10:00] and backwash icon displayed ). Press the
Menu/Confirm button and use the Up/Down buttons to set it to [2-10:00]. Press Menu/Confirm
to confirm the backwash time.
6) To change the Fast Rinse Time:
The fast rinse time is the amount of time (in minutes) that the system will rinse for.
For a neutralizer filter, set the fast rinse time to 6 minutes [3-06:00]. To change this, set the
programming mode to Fast Rinse Time ( [3‐10:00] and fast rinse icon displayed ). Press the
Menu/Confirm button and use the Up/Down buttons to set it to [3-06:00]. Press Menu/Confirm
to confirm the fast rinse time.
7) To change the Signal Output Mode
The signal output mode refers to when the system receives external function.
Leave this at its default, [b-01].
After configuring, press the Manual/Return button to exit programming mode.
Page 11
www.cleanwaterstore.com
Rev 12222019