Status codes

If a fault occurs during operation, specific status codes may be displayed. Faults
can result from the following:
-
-
-
-
If an error message appears on the display and if you cannot resolve the error
yourself:
1
2
3
Status codes caused by external factors
Number
(11)
(13)
(14)
(16)
(17)
Status codes in the event of a battery fault
Number
(22)
(23)
(24)
(25)
(26)
(29)
Status codes in the event of a charging error
Number
(31)
(32)
(33)
50
Battery is connected with reverse polarity
The voltage of the connected battery is unsuitable
The device has overheated
There is a software or hardware fault
Note the displayed status code: e.g. "Statecode (31)"
Note the configuration of the device
Contact After-Sales Service
Freely-defined text, which could for example include the contact details of
the dealer, can be displayed if the device is in an error state. More informa-
tion can be found in the "USB mode" section.
Cause
Mains overvoltage or undervoltage
External temperature sensor faulty
Electrolyte circulation faulty (pressure switch not switching)
External start/stop is not closed
Open circuit voltage detection triggered more than once during
charging (e.g. worn charging contacts)
Cause
Battery undervoltage
Battery overvoltage
Battery too hot (with external temperature sensor only)
Battery too cold (with external temperature sensor only)
Cell fault detected
Battery is connected with reverse polarity
Cause
Timeout in I1 phase
Timeout in U1 phase
Battery overvoltage in the I2 phase