Charging The Battery; Charging - Fronius Selectiva 2060 Operating Instructions Manual

Hide thumbs Also See for Selectiva 2060:
Table of Contents

Advertisement

Charging the battery

Charging

Danger due to escaping battery acid or explosion if faulty batteries are charged.
This may result in serious injury and damage to property.
Danger due to faulty charging settings or a defective battery.
This may result in serious injury and damage to property.
NOTE!
Risk of property damage if the charging plug contacts are very dirty.
The resulting increase in contact resistance can lead to overheating and sub-
sequent destruction of the charging plug.
1
The charger parameters can be set individually. More information on the charger
parameters can be found under "Configuration mode" in the "Display functions"
chapter. Ensure that the battery to be charged matches the configuration of the
battery charging system.
2
The charger detects that the battery is connected and starts charging. If start-up
delay is activated, then charging will start at the end of the set delay time. For
more information, see "Configuration mode" in the "Display" section.
During the charging process the display shows the following values:
-
-
-
-
-
WARNING!
Before charging, ensure that the battery to be charged is fully functional.
WARNING!
Before charging, ensure that the battery to be charged is fully functional.
Keep the charging plug contacts free from impurities and clean them if ne-
cessary
Connect the charger mains plug to the electrical mains supply
Connect the charging plug
or connect the
(+) charging lead to the positive pole of the battery and the
(-) charging lead to the negative pole of the battery
Current charging current (A)
Current charging voltage (V)
The charge already input (Ah)
Battery temperature with the "temperature-controlled charging" option
The time (hh:mm) since charging started
The display appears in standard mode.
The display shows the charger para-
meters:
-
Type of battery (e.g. wet)
-
Charging characteristic (e.g. IUI)
-
Nominal voltage (e.g. 48 V)
-
Capacity (e.g. 300 Ah)
-
Day of the week, date and time
25

Advertisement

Table of Contents
loading

Table of Contents