Status codes

If a fault occurs during operation, specific status codes may be displayed. Faults can result
from the following:
-
-
-
-
Battery fault:
If the battery signals a fault, the charger displays this fault as a battery fault including the
corresponding fault number for the battery. The respective fault is explained in the battery's
Operating Instructions.
If an error message appears on the display and if you cannot resolve the error yourself:
1
2
3
Status codes caused by external factors
No.
(11)
(12)
(13)
(14)
(15)
(16)
(17)
Status codes in the event of a battery fault
No.
(22)
(23)
(24)
(25)
Battery fault
The voltage of the connected battery is unsuitable.
The device has overheated.
There is a software or hardware fault.
Note the displayed status code: e.g. "Statecode (31)".
Note the configuration of the device.
Contact your authorised service centre
Freely-defined text, which could for example include the contact details of the dealer,
can be displayed if the device is in an error state.
Cause
Check grid voltage
Check grid (phase failure)
External temperature sensor faulty
Electrolyte circulation faulty (pressure switch not switching)
Control voltage not detected
External start/stop is not closed.
Open circuit voltage detection triggered more than once during charging (e.g. worn
charging contacts)
Cause
Battery undervoltage
Battery overvoltage
Battery too hot (with external temperature sensor only)
Battery too cold (with external temperature sensor only)