Index B500 Operating Instructions And Maintenance Instructions page 63

Hide thumbs Also See for B500:
Table of Contents

Advertisement

Maintenance Summary - 4.000 Operating hours
Maintenance Instructions
B500
DIE219EN - 05.06.2019
6.
Example: Exploded view of fine filter replacement (by FESTO)
1
Filter bowl
2
Separating disk
3
Filter cartridge (check retained particle size)
4
Filter receptacle
5
O-ring
Replace fine filter or microfilter. When removing the filter bowl, make sure
to include the O-ring (5), separating disk (2) and filter holder (4).
Unscrew filter bowl (1) from filter base body and remove filter cartridge (3) ,
and replace. Check O-ring (5) , replace if necessary. Reinstall all parts in
reverse order.
59

Advertisement

Table of Contents
loading

Table of Contents