APPENDICES
Number
Name
Error number that
SD50
Error reset
performs error reset
Bit pattern indicating
SD51
Battery low latch
where battery voltage
drop occurred
Bit pattern indicating
where battery voltage
SD52
Battery low
drop occurred
AC/DC DOWN
Number of times for
SD53
detection
AC/DC DOWN
Blown fuse
Number of module
SD60
number
with blown fuse
I/O module
I/O module verification
verification error
SD61
error module number
number
Annunciator
Annunciator number
SD62
number
Number of
Number of
SD63
annunciators
annunciators
SD64
SD65
SD66
SD67
SD68
SD69
SD70
Table of
SD71
detected
Annunciator detection
annunciator
number
SD72
numbers
SD73
SD74
SD75
SD76
SD77
SD78
SD79
App - 9
Special Register List (Continued)
Meaning
• Stores error number that performs error reset
• All corresponding bits go ON when battery voltage drops.
• Subsequently, these remain ON even after battery voltage has been returned to
normal.
• Same configuration as SD51 above
• Subsequently, goes OFF when battery voltage is restored to normal.
• Every time the input voltage falls to or below 85% (AC power)/65% (DC power) of
the rating during calculation of the CPU module, the value is incremented by one
and stored in BIN.
• Value stored here is the lowest station I/O number of the module with the blown
fuse.
• The lowest I/O number of the module where the I/O module verification number
took place.
• The first annunciator number to be detected is stored here.
• Stores the number of annunciators searched.
When F goes ON due to OUT F or SET F , the F numbers which go
progressively ON from SD64 through SD79 are registered.
F numbers turned OFF by RST F are deleted from SD64 to SD79, and are shifted
to the data register following the data register where the deleted F numbers had
been stored.
Execution of the LED R instruction shifts the contents of SD64 to SD79 up by one.
(This can also be done by using the INDICATOR RESET switch on the front of the
CPU of the Q3A/Q4ACPU.)
After 16 annunciators have been detected, detection of the 17th will not be stored
from SD64 through SD79.
SD62
0
SD63
0
SD64
0
SD65
0
SD66
0
SD67
0
SD68
0
SD69
0
SD70
0
SD71
0
SD72
0
SD73
0
SD74
0
SD75
0
SD76
0
SD77
0
SD78
0
SD79
0
Explanation
-------------------------------------------------
0<
SET
SET
SET
RST
SET
SET
SET
SET
SET
F50
F25
F99
F25
F15
F70
F65
F38
F110
50
50
50
50
50
50
50
50
50
1
2
3
2
3
4
5
6
50
50
50
50
50
50
50
50
50
0
25
25
99
99
99
99
99
99
0
0
99
0
15
15
15
15
15
0
0
0
0
0
70
70
70
70
0
0
0
0
0
0
65
65
65
0
0
0
0
0
0
0
38
38
0
0
0
0
0
0
0
0
110 110 110 151
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
B0
>
CPU error
SET
SET
F151
F210RSTF50
99 ...(Number
50
50
detected)
...(Number of
7
8
9
8
annunciators
detected)
50
50
99
99
99
15
15
15
70
70
70
65
65
65
38
38
38 110
0
151
151 210
(Number
0
0
210
0
detected)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
MELSEC-Q
Set by (When set)
U
S (Error)
S (Error)
S (Error)
S (Error)
S (Error)
S (Instruction
execution)
App - 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qcpuMelsec q00jcpuMelsec q00cpuMelsec q01cpu

Table of Contents