Nikon NPL-632 Instruction Manual page 76

Field station
Table of Contents

Advertisement

4
Applications
You can delete poor observations and recalculate if necessary. You can also select the
BS point.
If the angle between known point 1 and known point 2 (measured from the station point) is extremely acute or
extremely oblique, the resulting solution will be less reliable geometrically. For geometric reliability, select
known point locations (or station point locations) that are widely spaced.
1.
2.
3.
4.
5.
6.
7.
62
Field Station NPL-632 Instruction Manual
To start the resection, press
in the Stn Setup menu.
Resection
Enter the point name for the first observation
point (PT1).
Enter the target height and press
Sight PT1 and press
[MSR1]
To use the
softkey for F1/F2 measurements,
F2
see
Advanced feature: Measuring F1 and F2,
page
60.
To proceed to the next point, press
Enter the second point (PT2) and its height of
target.
Measure to PT2 and press
When the instrument has enough data, it
calculates the station (STN) coordinates.
or select
[2]
.
[ENT]
or
.
[MSR2]
.
[ENT]
.
[ENT]