Problem
Cord reel is not providing adequate
ground
Cord locked when accessory cord
was fully extended
Breaker or fuse trip out (GFCI
accessory or European models
only)
Cord could not extend fully
3A2592A
Cause
Cord is damaged
Cord or reel was installed incor-
rectly
Worn slip-ring /brushes
Slip-ring cover is assembled in the
incorrect position
Application does not conform to the
electrical rating of the reel
Wires are broken or shorted
GFCI models only: power was
removed from unit
Spring has too much tension
applied
Troubleshooting
Solution
Use ohmmeter to review ground
path and correct problem.
Review installation procedures
beginning on page 8 and correct
problem.
Replace worn slip-ring/brushes.
See Cord Reel Repair and Parts
manual.
Relocate slip-ring cover in correct
location. See Cord Reel Repair and
Parts manual.
Check electrical rating on reel label.
Do not attempt to use a reel that is
not rated for the application.
Replace all damaged wires.
Reset GFCI.
Release some of the spring tension.
See Decreasing Spring Tension,
page 14.