Outlet Thermistor; Outlet Thermostat - GE Profile DPGT650GH Technical Service Manual

High-efficiency dryer
Hide thumbs Also See for Profile DPGT650GH:
Table of Contents

Advertisement

Outlet Thermistor

The outlet thermistor is located on the back side of
the blower housing.
The outlet thermistor measures outgoing air
temperature and responds to temperature
changes.
The outlet thermistor provides temperature
change information to the display assembly.
The display assembly makes heating decisions
based on this information.
At room temperature, the outlet thermistor has
a resistance value of 10 K Ω +/-3%.
To remove the outlet thermistor:
1.
Remove the front panel and the drum. (See
and
.)
Panel
Drum
2.
Disconnect the wiring from the outlet thermistor.
Disconnect
Outlet Thermistor
3. Remove the Phillips-head screw that holds the
outlet thermistor in place.
Viewed From Rear
The outlet thermostat is located on the back side of
the blower housing.
Front
To remove the outlet thermostat:
1.
2.
3. Remove the 2 Phillips-head screws that hold the
Outlet Thermistor
– 29 –

Outlet Thermostat

The outlet thermostat monitors outgoing air
temperature.
If the outlet thermostat reaches a temperature
beyond its maximum temperature rating, it will
trip and disable the heating function only.
The heating function will be restored when the
outlet thermostat cools and resets.
The outlet thermostat on the electric model has
a trip temperature of 189°F (87°C) and a reset
temperature of 153°F (67°C).
The outlet thermostat on the gas model has
a trip temperature of 185°F (85°C) and a reset
temperature of 149°F (65°C).
Remove the front panel and the drum. (See
and
.)
Panel
Drum
Disconnect the wiring from the thermostat.
Disconnect
Outlet Thermostat
outlet thermostat to the blower housing.
Outlet Thermostat
Viewed From Rear
Front

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profile dpgt650ehProfile dpgt650ghww