3. Remove the 2 Phillips-head screws that hold the
heater assembly in place.
Inlet Thermistor
The inlet thermistor is located on the inside of the
inlet air duct on both the electric and gas models.
(See
Component Locator Views
•
The inlet thermistor measures the incoming
air temperature and responds to temperature
changes.
•
The inlet thermistor provides temperature
change information to the display assembly.
•
The display assembly makes heating and
blower decisions based on this information.
•
At room temperature, the inlet thermistor has a
resistance value of 227 K Ω +/- 5%.
To remove the inlet thermistor:
1.
Remove the Phillips-head screw that holds the
inlet thermistor access cover to the back of the
dryer.
2. Disconnect the wiring from the thermistor.
3. Remove the Phillips-head screw that holds the
thermistor in place.