Troubleshooting; Noise Emission Level; Maintenance - IMER MIX 60 PLUS Operating, Maintenance, Spare Parts Manual

Hide thumbs Also See for MIX 60 PLUS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
- Warning: Never start the mixer without the safety grid fi t-
ted; the cover is a safety device and must be fi tted to avoid
direct contact with the mixer blades.
11.1 APPLICATIONS
11.1.1 ADHESIVES FOR CERAMIC TILES, FLOORING AND
WALL CLADDING
Pour in the quantity of water as required for the relative product,
considering that the maximum mixer capacity 50 kg of adhesive.
Start the machine and during operation, pour the powder directly over
the plastic cover to obtain a smooth mixture.
- Warning: when mixing large quantities, pour the product
into the tank gradually.
11.1.2 PAINT
Pour in the required amount of paint and water.
- The use of acid, solvents, and other aggressive chemical
products is strictly prohibited.
11.1.3 CEMENT
Mix 60 PLUS can also mix mortar, cement, or lime provided that a
fi ne particle size is used.
- Warning: Avoid excessive stiffening of the mixture due to
the addition of too much cement, lime or other water absorbing
products.
12. EMERGENCY STOP
- In an emergency, press the red button and unplug the
mixer.
- The electric motor is protected from thermal overload;
if the motor overheats the mixer is shut down automatically.
Allow the motor to cool before resuming operation.
13. CLEANING
After each work shift and before prolonged periods of disuse, clean
the tank interior and exterior thoroughly.
- Always unplug the mixer from the mains before cleaning
(also when using brushes, cloths or scrapers etc.).
- Never operate the mixer during cleaning operations.
- When using water jets for cleaning, never direct the water at the
mixer drive unit.
- Do not use solvents or fl ammable liquids.

14. MAINTENANCE

- Warning: Always switch off the mixer and unplug from
the power supply before carrying out maintenance.
- Repairs to the electrical installation must be carried out exclusively
by qualifi ed personnel. Replacement parts must be original IMER
spare parts and must not be modifi ed in any way. The IMER MIX 60
PLUS is designed for minimum maintenance requirements. Howe-
ver, we recommend changing the reduction unit oil after 3000 hours
continuous duty with SAE 40 oil.
Check that the socket/plug contacts are clean. If oxidised, clean
immediately.
- Used oil is considered a special waste product and must
be disposed of in accordance with the law.
- Always ensure that signs and warning notices on the ma-
chine are clearly legible.
IMER INTERNATIONAL S.p.A.
MIX 60 PLUS

15. TROUBLESHOOTING

PROBLEM
The motor does not
start when switched
on
The motor does not
stop when the safety
grid is lifted
Motor starts with
diffi culty

16. NOISE EMISSION LEVEL

The noise emission level of the mixer is reported in table 2 (dB(A)
at 1 m)and the measured sound power level L
CONCRETE MIXER
MIX 60 PLUS
8
CAUSE
REMEDY
No power on power cable
Check power cables
Plug not inserted correctly
Ensure correct connection
in socket
Faulty power cable to
Change power cable
electrical panel
Loose wire in electrical
Reconnect wire
panel
Loose wire in motor
Reconnect wire
terminal board
Faulty main switch
Replace switch
Residual current circuit
Reset switch. If it does not
breaker tripped
reset, refer to a qualifi ed
electrician to check the
electrical system to ensure
complete safety.
Faulty limit switch
Replace limit switch
Mixture is too stiff
Reduce mixture quantity or
dilute and try again.
(EN ISO 3744).
WA
TABLE 2
Type of motor
dB(A)
ELECTRIC
230V 50HZ
59
220V 60HZ
GB
LWA
73