Vega WEIGHTRAC 31 Operating Instructions Manual page 19

Radiation-based sensor for mass flow detection
Hide thumbs Also See for WEIGHTRAC 31:
Table of Contents

Advertisement

WEIGHTRAC 31 • 4 ... 20 mA/HART - four-wire
Fig. 8: Mounting the sensor in the measuring frame
8
Screws M6 x 120 (4 pcs.)
9
Wedge lock washer M6 Nordlock (8 pcs.)
10 Cover plate (2 pcs.)
11 Clamp collar (4 pcs.)
12 Nut M6 (4 pcs.)
13 Sensor
2. Insert the sensor (13) laterally into the measuring frame beneath
the conveyor belt and place the sensor in the two clamp collars
(11).
Position the measuring width of the sensor below the conveyor
belt as close as possible to the center. Make sure that there is
sufficient distance between sensor and conveyor belt when the
belt is loaded.
3. Place the other two clamp collars (11) according to the illustration
above the clamp collars that are already in place (11).
4. Place a metallic cover plate (10) according to the illustration on
each upper clamp collar (11).
4 Mounting
8
9
10
11
13
11
9
12
19