In the left column (A), the encoded temperature change of the
corresponding heat curve is shown at defined times. In the right
column (B), the difference is depicted between the encoded set
increase and actual increase. As long as the value in the right
column is zero, the specified heat curve validated by Sirona is
precisely adhered to. For systematic deviations during the actual
sintering process, contact the Sirona customer service center.
Temperature deviations may occur during the warm-up and
cooling phases. These will not cause any operating faults.
Tip: Each time Hyper Terminal is restarted, the configured connection can
be directly selected by clicking on the defined icon with the corresponding
"Start"
name (e.g.
"Hyper Terminal"
11.2
Service codes
Service codes
F8540 / F08540
F8560 / F08560
F8561 / F08561
F6900
"Programs"
"Accessories"
/
/
/ inFire HTC).
Action
Reset the dial
Enter the serial number
Initialization of the battery time (days) and
heating time of the heating elements (hours)
Emergency door program for opening the door
11 RS232 interface
11.2 Service codes