Error: The Furnace Door Does Not Close - Dentsply Sirona inFire HTC speed Service Manual

Hide thumbs Also See for inFire HTC speed:
Table of Contents

Advertisement

8 Troubleshooting
8.2 Error without message on the display
28
Elimination
Install 30 mA circuit breaker.
8.2.11

Error: The furnace door does not close

Cause
Door sensor not seated correctly.
Elimination
Correct the position of the door sensor.
1. Loosen the screws marked with red paint (A) slightly and move the
door sensor down a few millimeters.
2. Re-tighten the screws (A) and check that the furnace is working
correctly. If the furnace door still does not close automatically after
program start without issuing an error message, move the door
sensor again by a few millimeters.
3. Check whether the furnace door is completely closed.
Dentsply Sirona
Service Manual inFire HTC speed
61 30 608 D3497
D3497.076.01.09.02 10.2018

Hide quick links:

Advertisement

Table of Contents
loading