CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (Oscillation Circuit)

4.3.4 Switching of operating voltage

(1) When OSC1 crystal oscillation circuit is used
The CPU system clock is switched to OSC1 or OSC3 by the software (CLKCHG register). In this case,
to obtain stable operation, the operating voltage V
software (VDC register).
OSC1 (crystal oscillation) operation:
OSC3 operation:
When OSC3 is to be used as the CPU system clock, it should be done as the following procedure using
the software: first switch the operating voltage V
msec or more for the above operation to stabilize, switch the clock after waiting 5 msec or more for
oscillation stabilization.
When switching from OSC3 to OSC1, turn the OSC3 oscillation circuit OFF after switching the clock
then set the operating voltage V
OSC1 → OSC3
1. Set VDC to "1" (1.3 V → 2.2 V).
2. Maintain 2.5 msec or more.
3. Set OSCC to "1" (OSC3 oscillation ON).
4. Maintain 5 msec or more.
5. Set CLKCHG to "1" (OSC1 → OSC3).
(2) When OSC1 CR oscillation circuit is used
When the CR oscillation circuit has been selected as the OSC1 oscillation circuit by mask option, 2.2 V
of V
necessary to operate with OSC1 and OSC3.
D1
OSC1 (CR oscillation) operation:
OSC3 operation:
Since the S1C63454 fixes the V
the OSC1 oscillation circuit by mask option, it is not necessary to switch the operating voltage V
software (VDC register). However, software control to switch the CPU system clock using the
CLKCHG register is necessary.
When OSC3 is to be used as the CPU system clock, it should be done as the following procedure using
the software: turn the OSC3 oscillation ON, switch the clock after waiting 5 msec or more for oscilla-
tion stabilization.
When switching from OSC3 to OSC1, turn the OSC3 oscillation circuit OFF after switching the clock.
OSC1 → OSC3
1. Set OSCC to "1" (OSC3 oscillation ON).
2. Maintain 5 msec or more.
3. Set CLKCHG to "1" (OSC1 → OSC3).

4.3.5 Clock frequency and instruction execution time

Table 4.3.5.1 shows the instruction execution time according to each frequency of the system clock.
Clock frequency
OSC1: 32.768 kHz
OSC1: 60 kHz
OSC3: 4 MHz
24
V
= 1.3 V
D1
V
= 2.2 V
D1
to 1.3 V.
D1
V
= 2.2 V
D1
V
= 2.2 V
D1
voltage value at 2.2 V when the CR oscillation circuit is selected as
D1
Table 4.3.5.1 Clock frequency and instruction execution time
Instruction execution time (µsec)
1-cycle instruction 2-cycle instruction 3-cycle instruction
61
33
0.5
for the internal circuits must be switched by the
D1
(VDC = "0")
(VDC = "1")
, turn the OSC3 oscillation ON after waiting 2.5
D1
OSC3 → OSC1
1. Set CLKCHG to "0" (OSC3 → OSC1).
2. Set OSCC to "0" (OSC3 oscillation OFF).
3. Set VDC to "0" (2.2 V → 1.3 V).
OSC3 → OSC1
1. Set CLKCHG to "0" (OSC3 → OSC1).
2. Set OSCC to "0" (OSC3 oscillation OFF).
122
67
1
EPSON
D1
183
100
1.5
S1C63454 TECHNICAL MANUAL
by

Advertisement

Table of Contents