PREPARATION FOR USE

Position the pump to ensure that air flow around the motor and cooling fan is unobstructed. Keep the motor and
cooling fan clean to ensure maximum cooling during operation.
For shipping purposes, a red shipping plug (A) is installed in the breather port on the top of the reservoir. Before
using, replace the shipping plug with the black breather cap supplied. Note: The breather port is separate from the
oil fill port (B). Oil fill port (B) uses a SAE #10 plug. Refer to the illustration on page 12.
Check the oil level of the pump prior to start-up. If necessary, add clean oil by removing plug (B) from the cover
plate. The reservoir is full when the oil level reaches the top of the sight glass.
Use only Enerpac
®
warranty null and void. Hydraulic oil is available to order under the following part numbers.
PART NUMBER
®
Enerpac
Part Number
Volume
Viscosity
IMPORTANT - Add oil only when the placing tool piston is in the fully forward position or the system will
contain more oil than the reservoir can hold.
Ensure that the mains power supply to the pump unit is turned 'Off'.
IMPORTANT – BEFORE PUTTING THE TOOL AND HOSE ASSEMBLY INTO SERVICE:
ENSURE THAT THE PUMP PRESSURE RELIEF VALVES HAVE BEEN SET IN ACCORDANCE WITH THE
INSTRUCTION ON PAGES 20 TO 22 AND THE MAXIMUM PRESSURES SPECIFIED FOR THE PLACING TOOL
AND HOSES.
ENSURE THAT BOTH ITEMS ARE PRIMED WITH HYDRAULIC FLUID IN ACCORDANCE WITH THE
PROCEDURE IN THE PLACING TOOL INSTRUCTION MANUAL AND THE INSTRUCTIONS ON PAGE 20.
Connect the hydraulic hose quick couplers to the pump unit before connecting the electrical control cable. Hoses
and control cable must be connected in this order and disconnected in reverse order.
Switch on the mains supply to the hydraulic pump unit. Wait 5 seconds for the pump unit to complete the boot
sequence, before pressing the trigger switch. When all set the LCD screen on the pump unit will display 'AVDEL' and
'0 bar'.
During the boot sequence the pump control system identifies any trigger operation as a potential malfunction and
16
HF oil – the use of any other oil may cause the pump to malfunction and will render the Enerpac
HYDRAULIC OIL
07992-00081
HF-95X
1 Litre
32 mm
2
/s
07992-00082
07992-00083
HF-95Y
5 Litres
32 mm
2
/s
®
HF-95T
20 Litres
32 mm
2
/s