Pump Lcd Menus And Operating Instructions - Stanley Enerpac PRO Series Manual

Table of Contents

Advertisement

prevents the motor from starting. The LCD screen will display 'BUTTON FAULT' in this instance. Reset by switching
off the power supply for 10 seconds.
Depress and release the placing tool trigger switch a few times to almost the full stroke of the tool to circulate
hydraulic fluid.
Observe action of tool. Check for fluid leaks and ensure that in the idler mode the piston is in the fully forward
position.
3.3

PUMP LCD MENUS AND OPERATING INSTRUCTIONS

Note: This is not applicable to pump models 76506-02000 and 76507-02000 – refer to
section 3.6.
Connect the unit to the power supply and switch on. Wait 5 seconds for the pump unit to complete the boot
sequence, before pressing the trigger switch. When all set, the LCD screen on the pump unit will display 'AVDEL'
and a numeric display of the current pump-pressure. This should read '0 BAR'.
During the boot sequence the pump control system identifies any trigger operation as a potential malfunction and
prevents the motor from starting. The LCD screen will display 'BUTTON FAULT' in this instance. Reset by switching
off the power supply for 10 seconds.
In addition to the tool trigger switch, which is used to operate the basic function of the pump, the pump control unit
also has four buttons below the LCD screen that are the main interface between the operator and the unit.
The On/Off MOTOR button toggles the motor Off. The Off function is available on this button even if the pump is
not in the LOCAL mode, but is operated by the placing tool.
The MENU button enables the operator to step from normal operational mode into menus. With repeated pressing
the operator steps through the various menus. Pressing the Menu button also saves any changes made. To return to
the normal operational mode, press and hold the Menu button for two seconds or don't push any button for 60
seconds.
The Down Arrow and Up Arrow buttons serve two purposes. When the display shows one of the menus, the Down
Arrow and Up Arrow buttons are used to step through the menu's options. When the pump is placed in LOCAL
Mode, the Down Arrow and Up Arrow buttons switch the valve solenoid between the pull and return side of the
placing tool. The placing tool trigger is non-operational in LOCAL mode.
AVDEL
0
On/Off
Menu
SCREEN 1
BAR
Down
Up
Arrow
Arrow
17

Advertisement

Table of Contents
loading

Table of Contents