4.3

CHANGING THE FILTER ELEMENT

A return line filter may be ordered as an accessory to the pump. The filter element should be replaced every 250 hours, or
more frequently in dirty environments. The filter manifold is equipped with a 25 psi (1.7 bar) bypass to prevent over pressure
rupture if filter plugging occurs. Filter element replacement part number is PF25.
®
Enerpac
HF Hydraulic Oil General Safety Data
First Aid
SKIN:
Unlikely to cause harm to the skin on brief or occasional contact but prolonged or exposure may lead to dermatitis. Wash skin
thoroughly with soap and water as soon as reasonably practicable. Remove heavily contaminated clothing and wash
underlying skin.
Launder contaminated clothing.
ORAL:
Unlikely to cause harm if accidentally swallowed in small doses, though larger quantities may cause nausea and diarrhea.
If contamination of the mouth occurs, wash out thoroughly with water. Except as a deliberate act, the ingestion of large
amounts of product is unlikely. If it should occur, do not induce vomiting; obtain medical advice. Take person to nearest
medical centre.
EYES:
Unlikely to cause more than transient stinging or redness if accidental eye contact occurs.
Wash eyes thoroughly with copious quantities of water, ensuring eyelids are held open. Obtain medical advice if any pain or
redness develops or persists.
DISPOSAL:
Remove all spills with inert absorbent material. Ventilate spill area. Place contaminated materials in a disposable container
and dispose in a manner consistent with local regulations.
Fire
FLASH POINT: 200°C.
Extinguish with either dry chemical, foam or carbon dioxide. Do not enter confined space without self contained breathing
apparatus.
Handling
Use barrier cream or oil resistant gloves.
Storage
Undercover and consistent with local regulations for inflammable material.