Rigging procedures
Rigging procedures
Wall-mounting Syva
type of deployment
rigging accessories
tools
additional material
min number of operators
Secondary safety
Secure a DIN-580 eye bolt to the dedicated insert on the enclosure to implement a secondary safety.
The speakON connector is only accessible if Syva Wall is used with a wedge.
Syva Wall can be mounted on a truss bridge.
Refer to
Mounting a truss clamp on Syva Wall
Assembly
Procedure
1. Remove the safety pin and divide Syva Wall into base and bracket.
bracket
base
44
wall-mount
Syva Wall
torque screwdriver
T30 Torx bit
2 x M6 screws and anchors (depending on wall material)
1
(p.51).
Syva owner's manual (EN) version 1.0