TROUBLESHOOTING
Problem
When rebooting the terminal,
an error message appears:
"RADIO ERROR".
The
boot
seems
correct, but Formula Color™
Wi-Fi does not connect to
the wireless LAN or cannot
reach the host.
Upon boot, the terminal locks
up
while
executing
program or a driver.
Check configuration correctness, since one of the
following conditions may have occurred:
-
some files may have been deleted;
-
an incorrect driver may have been loaded for
the Radio card mounted on the Formula
Color™ Wi-Fi (please also refer to the driver
manuals).
If problem persists, contact the nearest Datalogic
distributor for technical assistance.
to
be
Check configuration correctness, since one of the
following conditions may have occurred:
-
Formula Color™ Wi-Fi is out of access point
coverage area;
-
radio
Encription, safety parameters, etc.) may have
been set incorrectly (please also refer to the
driver's manual);
-
TCP/IP configuration files may have been set
incorrectly (terminal IP address, Subnet Mask,
Default Router, etc.);
-
the configuration files of running application
may have been set incorrectly (DL-TCL, Web
Client).
If problem persists, contact the nearest Datalogic
distributor for technical assistance.
Reboot the terminal and press the "FUNC" - "F4"
keys in sequence during the memory check. This
a
implies a "Step-by-step" boot activation.
Press the "y" key to confirm (execute) each
program/driver until the one that locks the terminal.
Once found the locking program/driver, repeat the
procedure from the beginning and skip the
execution
pressing the "n" key. Replace the program/driver.
If problem persists, format the disk C: and load a
fresh configuration.
If problem still persists, contact the nearest
Datalogic distributor for technical assistance.
Possible Solution
configuration
files
of
the
incorrect
6
(ESS_ID,
Wep
program/driver
by
31