  • Page 4 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Page 5: Table Of Contents

    CONTENTS GENERAL INFORMATION..........1 Terminal Description ............1 Application Development Programs ........ 3 Downloading EasyGen™ Demo........4 Accessories ..............4 Package Contents ............5 SAFETY REGULATIONS ..........6 General Safety Rules............6 Laser Safety ..............7 FCC Compliance ............11 CONNECTIONS ............
  • Page 7: General Information

    Windows environment. The EasyGen™ Demo Version with five ready-to-use example applications can be downloaded from the Datalogic web site free of charge. They cover the most common operating requirements in data collection, assisted sales, inventory and goods picking, thus making the Formula Wizard™...
  • Page 8 F732-E WIZARD™ Figure 1 - F732-E terminal overview Key: Laser beam output window Reset key (protected) Two color LED Cradle communications window Battery charger contacts...
  • Page 9: Application Development Programs

    The icons which can The battery be controlled by the charge status application program Time F732-E WIZARD LASER MICRO TERM DATALOGIC S.P.A. 4 LINES 16 CHARS Figure 2 - Terminal display APPLICATION DEVELOPMENT PROGRAMS "C" ANSI standard The Formula 732-E terminal is fully programmable in C language, thus solving even the most complex application needs.
  • Page 10: Downloading Easygen™ Demo

    F732-E WIZARD™ DOWNLOADING EASYGEN™ DEMO completing electronic form site, http:\\www.datalogic.com\pdc\easygen_demo.htm, download for free the EasyGen™ Demo Software package containing the following items: • EasyGen™ Demo Version (user-friendly and highly productive application generator) • SysTools™2001 (efficient utility for data exchange with the F732-E terminal) •...
  • Page 11: Package Contents

    GENERAL INFORMATION PACKAGE CONTENTS The F732-E terminal package includes: − n. 1 F732-E terminal complete with batteries; − n. 1 cradle F952 with power supply; − n. 1 cable 94A054000 for serial connection; − n. 1 user's manual − n. 1 test chart Remove all components from their packing and check that they are in good condition and that they correspond to the shipment documents.
  • Page 12: Safety Regulations

    F732-E WIZARD™ SAFETY REGULATIONS Read this manual carefully before performing any type of connection or repair on the terminal. The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this NOTE manual.
  • Page 13: Laser Safety

    SAFETY REGULATIONS LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. Laser beam output window AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX.
  • Page 14 F732-E WIZARD™ LA LUCE LASER DIE LASER- LE RAYON LASER A LUZ LÁSER È VISIBILE STRAHLUNG IST FÜR EST VISIBLE À ES VISIBLE AL ALL'OCCHIO DAS MENSCHLICHE L'OEIL MU ET IL OJO HUMANO UMANO E VIENE AUGE SICHTBAR UND EST ÉMIS PAR LA...
  • Page 15 SAFETY REGULATIONS ITALIANO Le seguenti informazioni vengono fornite dietro direttive delle autorità internazionali e si riferiscono all’uso corretto del terminale. NORMATIVE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione: CDRH 21 CFR 1040 e EN 60825-1.
  • Page 16 F732-E WIZARD™ FRANÇAIS Les informations suivantes sont fournies selon les règles fixées par les autorités internationales et se refèrent à une correcte utilisation du terminal. NORMES DE SECURITE LASER Ce produit est conforme aux normes de sécurité laser en vigueur à...
  • Page 17: Fcc Compliance

    SAFETY REGULATIONS FCC COMPLIANCE This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference which may cause CAUTION undesired operation.
  • Page 18: Connections

    F732-E WIZARD™ CONNECTIONS CRADLE To make the F732-E terminal operative, it is necessary to insert it in the Formula 952 Transceiver charger cradle which has been previously connected to the power supply and to a host computer with an available RS232 serial line.