4-1-3. Connection of Finished Inspection JIG and Lens Adjustment Program
(ActuatorChecker.exe)
Note:
Confirm "4-1-2. Lens Adjustment Program (ActuatorChecker)" has been completed before this procedure is executed.
Equipment
• Personal Computer
• USB cord with connector
• Finished Inspection JIG (AC100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1.
Connect equipment and checking lens as shown Fig.4-1-20.
Finished Inspection JIG
2.
Turn on the finished inspection JIG.
3.
Turn on the personal computer.
4.
Start up "ActuatorChecker.exe" from an arbitrary folder, conform that start up program normally.
Note:
Turn off the finished inspection jig after use.
SAL24105 (3.5-4.5/24-105) (24-105mm F3.5-4.5)
Lens
Fig.4-1-20