MCD Selection

Description
When multiple MCD controllers exist it becomes necessary to select which
is to be controlled. Running this function displays a selection dialog box
from which the desired controller is selected. When a controller is selected
the status information is returned in the argument. The selected controller
ID is returned with normal completion, and 0xffff(-1) is returned in the
case of an error.
Function Name
WORD SelectSensorUnit(Status);
Format
WORD SelectSensorUnit(SENSOR_STATUS*);
Arguments
Status ・・・・ MCD controller status information.
Return Values
0 〜 7:Normal completion (ID number for selected controller)
0xffff(-1):No MCD controller connected
Specify the pointer for the SENSOR_STATUS structure.
Structure the same as for the CheckSesnor function.