Eliminates the need for the operator to perform
'current spans' and manual calculations to
determine CP currents along the pipeline that require
connection to the pipeline.
Is designed for the Pipeline Industry with guidance
and support from Gas Industry leaders.
The PCM
is one part of the Radiodetection Pipeline
+
Product range, which also includes the Stray Current
Mapper and Smart Interrupter.
PCM
Transmitter
+
The PCM
system's specialized constant current high-
+
power transmitter allows for long range signal detection
of up to 30km (20 miles). Significantly fewer pipeline
connection points are needed thereby reducing the time
required to evaluate a section of pipeline.
The transmitter has three operating modes that enable
both distribution and transmission pipeline systems to be
effectively mapped.
Connecting the PCM
is straightforward, and the
+
transmitter's current reading LCD and power indicating
LEDs help the operator to choose the best settings for
the specific pipeline application.
For PCM
Transmitter operating instructions, please refer
+
to Section 2.
PCM
Receiver
+
The handheld receiver unit is used to locate the pipeline,
even in heavily congested areas. The receiver provides
the operator with a measurement of depth current
strength and direction of the near DC signal applied by
the system's transmitter.
The receiver makes the required calculations and
instantaneously displays the results. This provides the
operator with an improved method that accurately
troubleshoots the CP system by pinpointing metallic
contacts and locating areas of coating defects.
For PCM
receiver operating instructions, please refer
+
to Section 3.