User Manual
D750
DC Power Supply

4.2.7 Command Set Description

4.2.7.1 General guides

1. Any command or argument may be in capital letters or small letters.
2. In commands with an argument, a space must be between the command and the
argument.
3. For any command that sets a numeric value, the value may be up to 12 characters
long.
4. Carriage Return: If the CR character (ASCII 13) is received by itself, the power supply
will respond with "OK" and CR.

4.2.7.2 Command set categories

The D750 series command set is divided into four categories as follows:
1. Initialization control
2. ID control
3. Output control

4.2.7.3 Initialization control commands

#
Command
1
ADR n
2
RST
3
RMT
4
RMT?
5
\
62
│ www.deltaww.com
Description
ADR is followed by address which can be 0 to 30 and is used to access the
power supply.
Reset command. Brings the power supply to a safe and known state:
Output voltage: zero,
Output current: zero,
Output: Off,
FOLD: Off,
Sets the power supply to local or remote mode:
1. RMT 0 or RMT LOC, sets the power supply into Local mode.
2. RMT 1 or RMT REM, sets the unit into remote mode.
3. RMT 2 or RMT LLO, sets the unit into Local Lockout mode (latched
remote mode).
Returns the Remote mode setting:
1. "LOC"-The unit is in Local mode.
2. "REM"-The unit is in Remote mode.
3. "LLO"-The unit is in Local Lockout (latched remote) mode.
Repeat last command. If \<CR> is received, the power supply will repeat
the last command.
Remote: non-latched remote,
Auto-start: Off,
OVP: maximum,
UVL: zero