Rear Panel Sw1 Setup Switch; Sw1 Position Functions - Delta D750 User Manual

Table of Contents

Advertisement

User Manual
D750
DC Power Supply

3.1.5.1 SW1 position functions

Refer to Table 3-3 for description of SW1 position functions. The factory default setting is
Down for all positions.
Table 3-3: SW1 positions functions
Position
SW1-1
SW1-2
SW1-3
SW1-4
SW1-5
SW1-6
SW1-7
SW1-8
SW1-9
31
│ www.deltaww.com
Function
Output Voltage Remote
analog programming
Output Current Limit
Remote analog
programming
Programming range select
(Remote voltage/resistive)
Output Voltage and
Current Monitoring range
Shut Off logic select
RS232/485 select
Output Voltage Resistive
programming
Output Current Limit
Resistive programming
Enable/Disable control
Down (Factory default)
Output Voltage
Programmed by Front
Panel
Output Current Limit
Programmed by Front
Panel
0-5V / (0-5Kohm)
0-5V
On: Open
Off: Short
RS232 interface
Output Voltage
Programmed by External
Voltage
Output Current Limit
Programmed by External
Voltage
Rear panel Enable/
Disable control is not
active
Up
Output Voltage
Programmed by remote
analog External Voltage or
External Resistor
Output Current Limit
Programmed by remote
analog External Voltage or
External Resistor
0-10V / (0-10Kohm)
0-10V
On: Short
Off: Open
RS485 interface
Output Voltage
Programmed by External
Resistor
Output Current Limit
Programmed by External
Resistor
Rear panel Enable/
Disable control is active

Advertisement

Table of Contents
loading