Technical data
Power supply
Logic supply PS
Intrinsic current consump-
tion at nominal operating
voltage 24 V from PS
Diagnostics message, under-
voltage in logic supply PS
Load supply PL
Intrinsic current consump-
tion at nominal operating
voltage 24 V from PL
Diagnostics message, under-
voltage in load supply PL
Tab. 16: Power supply
16
[V DC]
24 ± 25%
[mA]
Typically 40
< 18
[V DC]
[V DC]
24 ± 25%
[mA]
Typically 5
£ 17.7
[V DC]
Festo — CPX-AP-A-12DI4DO-M12-5P — 2022-07