LPG CONVERSION MODEL EFEP916
This appliance is supplied set up for Natural Gas usage.
A conversion kit is included with the product for Universal
LPG usage. The conversion kit contains 7 injectors and
1 LPG sticker.
Please follow the procedure below if a conversion to suit
UNIVERSAL LPG is required:
1
Remove the hotplate trivets, burner caps and
burner crowns to access the hotplate injectors.
Replace the factory fitted injectors with the
appropriate injectors, as supplied. Refer to injector
orifice table for injector sizes. The injector size is
stamped on the side of the injector.
2
Unscrew the top hat nut from the regulator. The top
hat nut and control pressure spring assembly will
disengage as an assembly.
3
Unscrew the threaded pin from top hat.
4
Upturn threaded pin, so spring is free and screw
pin back into the top hat until firm.
5
Refit the top hat nut assembly to the regulator
ensuring that it is fully screwed down. The regulator
is now set for connection to LPG.
6
Turn on the gas supply and at each new
connection check for leaks using soapy water.
Each hotplate valve should be turned on, one at a
time, and the injector hole blanked off for several
seconds.
7
The operation of the regulator can be confirmed by
connecting a manometer to the pressure test point
located on the side of the regulator body adjacent
to the outlet.
With the appliance operating check the outlet
pressure:
when all burners of the appliance are operating
at maximum,
when the smallest burner of the appliance is
operating at minimum.
Under these conditions the outlet pressure should
not vary from the nominal outlet pressure of 2.60kPa
by more than ±0.52kPa.
8
If the regulator appears to not be performing
satisfactorily then check the following points:
If the outlet pressure is consistently too low then
the inlet pressure may be too low and adjustment
of an upstream regulator may be needed, or an
upstream regulator or valve with insufficient flow
capacity may be present in the gas supply line.
If this is suspected then it may be necessary to
repeat the checks whilst measuring both the
inlet and outlet pressure to determine if the inlet
pressure is in the range 2.75 – 7.00kPa.
Check that the insert has been fitted correctly.
Check that the turret screw is fully screwed
down.
Check that the regulator has been fitted to the
gas supply line in the correct orientation, the
arrow on the base of the body indicates the
direction of gas flow.
A
Top hat nut assembly,
fully screwed down
C
Configuration for
Natural Gas
E
G
Flame size adjusted to
maximum
Flame size adjusted to
minimum
NOTE: The cooker MUST be tested after installation,
before handing over to the customer. You MUST
have a manometer and a connecting tube.
B
Turn top hat nut
anti-clockwise
and remove
D
F
Configuration for LPG
H
Bypass screw
Control knob shaft
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efep956Efep916Evep916Eve915dsea